Products, solutions & engineering services
Generation and protection are engineered together, by one team, under one contract. Design, approvals, supply, construction, commissioning and maintenance are managed by that team, with specialist work brought in where a project requires it.
Generation
Solar EPC
Turnkey C&I and residential solar, rooftop and ground-mounted, from survey and design to grid connection. Utility-scale work is delivered alongside solution partners.
Mini-grid & off-grid
Solar mini-grids, off-grid and hybrid systems for sites without reliable grid supply.
Solar irrigation
Solar pump systems for agricultural and estate applications.
Solar street lighting
Industrial-grade solar street lighting for roads, campuses and estates.
Solar EV charging
Solar EV charging stations for workplaces, campuses and commercial sites.
Storage & protection
Battery energy storage
Peak shaving, load shifting and backup for critical loads, specified where the load profile requires storage.
Lightning protection
Measured risk assessment and lightning protection systems, executed to IEC 62305 and NF C 17-102:2011.
Surge protection
Coordinated Type 1, 2 and 3 SPDs for inverters, switchgear and instrumentation.
Chemical earthing
Low-impedance earth systems, verified by soil resistivity and earth resistance testing.
Engineering & support
Design consultancy
Survey review, system design, layout and SLD, yield analysis and energy audit.
BSTI/BUET & net-metering
Application-to-approval support with BPDB, DPDC, DESCO and REB.
Electrical & substation
HT/LT distribution, substation works and upgrades.
Operation & maintenance
Preventive maintenance, cleaning, inverter servicing and performance monitoring, under a separate O&M contract.
Components supply (supply-only)
Modules, inverters, storage and balance-of-system items supplied against a specification, without EPC scope.
What we can build
The engineering scope
- Commercial & industrial (C&I) and residential turnkey solar: rooftop and ground-mounted
- Utility-scale and floating solar, delivered alongside solution partners
- Battery energy storage systems (BESS)
- Lightning protection systems (LPS), surge protection and earthing
- Solar irrigation pumps, solar street lights and solar EV charging stations
- Electrical, substation and net-metering support
Who we build for
Any home or industrial need
Lightning protection & earthing
A separate engineering discipline, not an accessory to the solar contract
A rooftop solar plant raises a conductive structure above a factory that may never have been assessed for lightning risk. UCC engineers generation and protection together, under one contract. Protection work is executed to IEC 62305 and NF C 17-102:2011 as specified for each project, and every installation begins with a measured risk assessment.
- 01
Direct strike
Air terminals, down conductors and structural bonding sized to the calculated strike risk of the specific site.
- 02
Surge protection
Coordinated Type 1, 2 and 3 SPDs protecting inverters, switchgear, PLCs and process instrumentation.
- 03
Earthing & bonding
Chemical earth systems delivering a low-impedance reference, verified by soil resistivity and earth resistance measurement.
- 04
Personal protection
Step and touch potential control in occupied and working areas.
How a lightning risk assessment runs
- 1
Brief & scope
Assets, occupancy and process criticality.
- 2
Site survey
On-site measurement of earthing, bonding and interconnectivity.
- 3
Risk calculation
Calculated risk against tolerable thresholds, per IEC 62305.
- 4
Report & recommend
Documented findings and a specified protection system.
Operations & maintenance
We stay connected after the ribbon is cut
40 sites are under an active O&M contract (October 2026). Generation is metered at every monitored plant; avoided emissions are calculated from that metered generation using a stated grid emission factor, for buyer sustainability audits, Higg and BSCI reporting and brand ESG requirements. Actual generation depends on site conditions, weather, module degradation, maintenance and the contract.
Preventive maintenance
Scheduled inspection of modules, mounting, DC and AC systems.
Module cleaning cycles
Soiling-loss management matched to site conditions.
Inverter servicing
Firmware, filters and fault attendance by trained engineers.
Performance monitoring
Generation tracked against the commissioned yield model.
Local spares & warranty
Spares from in-country stock; warranty claims raised and tracked by the team that installed the plant.
B2B solar components & accessories
Supply-only for developers, EPCs and dealers
A supply-only business for developers, EPC contractors and dealers.
Solar modules
Monocrystalline and bifacial modules.
Solar inverters
On-grid, off-grid, hybrid, micro and central inverters.
Battery energy storage
Large-scale storage systems, hybrid controllers and small home-storage units.
Mounting structures
Roof and ground mounting systems, rails, clamps and fixings.
DC & LT cables
Solar DC cable, LT cable and cable management.
Connectors & junction boxes
MC4-type connectors, combiner and junction boxes.
Protection devices
SPDs, DC isolators, fuses and earthing components.
Monitoring & O&M accessories
Weather stations, data loggers, energy meters, cleaning brushes and spares.
Distribution & support network
Why supplying the trade makes UCC a steadier contractor
A contractor that also supplies the trade carries inventory, holds the manufacturer relationship and has a reason to stay reachable after handover. Spares come from stock rather than a fresh import cycle, and a warranty claim goes to the same office that built the plant.
Stock held in country
Modules, inverters and balance-of-system items are carried as distribution stock, not ordered per project.
Direct OEM relationships
Equipment is sourced from the manufacturer without an intermediate importer.
Warranty handled locally
Claims are raised and tracked by the organization that installed the plant.
Partner and dealer supply
UCC supplies other partners and dealers alongside its own project work.
Ten branches and warehouses
Nationwide footprint supporting delivery, spares and service response.
Technical support
Product selection, sizing and commissioning support for trade customers.
Authorized national distributor: renewable energy
Brands UCC is authorized to distribute
Hopetrek
Inverters and balance-of-system equipment
LPI
Lightning protection & earthing systems
SolaX Power
Solar inverters and battery energy storage systems (BESS)
Victron Energy
Off-grid and hybrid power systems
Brands integrated on our projects
Module, inverter and balance-of-system brands installed on UCC projects.
- Inverters
- FroniusGoodWeHuaweiSMASolisSungrow
- Solar modules
- AstronergyCanadian SolarJA SolarJinko SolarLONGi SolarRECTrina Solar
- Cables & connectors
- LAPPTKG
- Mounting structures
- AntaiGoomaxhqmount
Diverse financing options
A commercial model to fit your need
CAPEX
You own the plant
- You fund the full system cost
- You own the asset and all its generation from day one
- Payback depends on tariff, load profile and system size
- UCC delivers the EPC; O&M is available under a separate contract
Best when capital is available and payback is the priority
OPEX / RESCO
We invest, you buy the power
- No upfront investment from you
- The plant is financed, built and operated under a separate agreement
- You pay for the solar energy you consume, at an agreed tariff
- Any asset transfer at the end of the term is defined in the agreement
Best when capital is committed elsewhere
Third-party finance
Financed through a lender
- Structured with IDCOL or a commercial lender, subject to the lender's eligibility criteria
- Ownership, repayment and security terms are set by the financing agreement
- Repayment can be planned against the plant's estimated energy savings
- UCC supports the financing application
Lease arrangements are assessed case by case; ownership and transfer terms are set in each agreement
Design criteria, acceptance tests, warranties and performance obligations are defined in each project contract.
Request a site & energy assessment
We survey the roof, read twelve months of your electricity bills, model the generation and return a sized system with a costed payback, all before any commitment.